- Ensure derrick is level
- 36” bit on floor
- Sufficient 9” drill collars, on rack, strapped (with top drive picked up prior spud)
- Sufficient 8 ½” drill collars, x/o to reach csg point on rack, strapped
- 10 stands 5” drill pipe made up and in derrick
- 2 stds HWP drill pipe in derrick, pup jts available for space out.
- 2 x Stabilisers 36” x 2 and pony DC ready, strapped ( if not one piece)
- Ultra seal pill mixed 30 m3
- Hi-vis spud mud mixed, mud system lined up – 250 m3
- Cellar jet and centrifugal pump functioning
- Contractor “C” plate on floor
- Float equipment for inner string running tool, centralizers
- DP centralizers, nails available
- 30” casing laid out & strapped. 7 joints
- Casing handling tools ready
- Casing dope. Baker lock in stock
- Circulating/cementing swedge available
- 18 5/8” casing on racks
- 18 5/8” pup joints range 1
- 18 5/8” Centralizers
- 18 5/8” Stop collars and Nails
- 18 5/8” Circulating head
- 18 5/8” Stinger for stab in shoe
- 18 5/8” Stinger repair kit
- 18 5/8” Landing stinger combo
- Riser in cellar, check flow line connection compatible
- Cement 60tonne, Bentonite 85 tonne & Barite 100 tonne . On site
- Jars on location – shock sub surface to 16” hole 2 Jars 8” 1 Shock 9.5”
- Water pit full and deliverable to mud system Pump checked for rate
- Survey tool ready, totco ring inserted
- Have cutting and welding equipt. ready plus welder first well 1 plus backup
- Have cementers check cmt quantity for next job
- Top Drive if available functions correctly backups ok?
- Swivel available, tested and ready for install in case of top drive failure
- High pressure wash gun
- Screens for Shakers & Skalpers, Mud cleaner screen blanked